Intense Pulsed Light (IPL) therapy
Dermatology & Aesthetics
estimated about CNY 1800-4500
Disclaimer: This site is a medical service platform; some page content is AI-assisted. Health-related information does not constitute medical advice. If you have any questions, please consult a healthcare professional. See full disclaimer
Description
A non-laser light-based treatment using broad-spectrum pulses to address photodamage, unwanted hair, and vascular lesions like telangiectasias and rosacea.
Main Uses
Primary clinical uses include: 1) Non-ablative photorejuvenation for facial skin texture, pore size, and diffuse redness improvement; 2) Permanent hair reduction on face and body (especially for dark, coarse hair); 3) Treatment of benign vascular lesions (e.g., telangiectasias, facial erythema, rosacea-associated vessels); 4) Adjunctive management of mild-to-moderate acne vulgaris via sebaceous gland targeting and anti-inflammatory effects.
Normal Range
M22王者之冠综合光疗 is not a diagnostic laboratory test but a non-invasive cosmetic medical device treatment using intense pulsed light (IPL) and Nd:YAG laser technologies. It has no numerical 'normal range' or quantitative biomarkers; clinical parameters (e.g., fluence: 10–60 J/cm², pulse duration: 1–100 ms, wavelength: 515–1064 nm) are individually calibrated based on skin type, target (melanin, hemoglobin, water), and indication—not standardized universal values.
Low Values - Possible Causes
N/A — This is not a biological assay with measurable 'low values'. Suboptimal outcomes (e.g., poor hair reduction or vascular clearance) may result from: 1) Inadequate fluence for patient’s skin/hair characteristics, 2) Improper skin cooling or device calibration, 3) Insufficient treatment sessions or long intervals between sessions, 4) Hormonal influences (e.g., PCOS-related hirsutism), 5) Use of photosensitizing medications or recent sun exposure.
High Values - Possible Causes
N/A — No 'high values' exist as it is not a quantitative test. Adverse effects (e.g., burns, hyperpigmentation, purpura) may occur due to: 1) Excessive fluence or inappropriate wavelength selection, 2) Treatment on tanned or Fitzpatrick skin types V–VI without proper settings, 3) Operator inexperience or device malfunction, 4) Pre-existing photosensitivity disorders (e.g., lupus), 5) Concurrent use of retinoids or chemical peels within 1–2 weeks prior.
estimated about CNY 1800-4500
Related Items
Intense Pulsed Light therapy
estimated about CNY 800-2000
picosecond laser pigment removal
estimated about CNY 1500-4000
Fractional CO2 laser resurfacing
estimated about CNY 3000-8000
Non-ablative fractional laser (1550 nm)
estimated about CNY 1200-3000
Q-switched Nd:YAG laser nevus ablation
estimated about CNY 300-1200
Q-switched alexandrite laser tattoo removal
estimated about CNY 1000-3500